SilverStone Tundra TD02-E AIO Liquid CPU Cooler Review

SilverStone is no stranger to us when it comes to All-In-One liquid CPU coolers. The new Tundra Series TD02-E AIO is SilverStone's updated version of its TD02 120mm dual fan cooler. SilverStone is not very clear on what exactly is better about this cooler, but we will put it through its paces to see if we have a better AIO.

Introduction

SilverStone has been on a roll in the last few years releasing high quality products that break away from the norm. Its cases such as the Raven and Fortress use a ninety degree rotated layout and have been well received by the community. SilverStone power supplies have similarly received lots of accolades around our offices. Last and certainly not least ,we have reviewed its cooling products which have performed well and used new cutting edge technology. It would be easy for a company with this sort of success to sit back and reap the benefits but SilverStone continues to do things different and release new products.

Today's review looks at SilverStone's newest all-in-one water cooler the Tundra Series TD02-E that sells for around $85. The TD02-E is am updated version of the Tundra TD02 we looked at a while back. SilverStone has made some minor updates and some big updates. Let's see if SilverStone can keep the good times rolling with their newest product.

Article Image

System Setup

Today's review takes place on our fourth generation [H]ard platform. The test bed consists of the ASUS Z87-Deluxe motherboard, eight gigabytes of Corsair 1600 MHz DDR3 RAM and the Intel Core i7-4770K.

Article Image

Test Methods

CPU

The biggest change you will notice is the removal of hardware testing. In recent years, Intel has shifted its methods of testing to software based and so we find it acceptable to do the same.

GPU

Once again we have an integrated GPU in our processor which alleviates the need for a discrete one. With the removal of a discrete GPU comes the advantage of not having an additional variable to account for.

The iGPU will not create any anomalies in our testing as long as we practice consistent testing methods.

Case

Corsair was kind enough to provide us with its Carbide series chassis. It provides excellent airflow and interior space and is a good reflection on current case design.

Thermal Paste

Noctua's NT-H1 thermal paste was selected as the thermal interface material (TIM) of choice for a few key reasons. The thermal paste has been shown to provide excellent thermal conductivity allowing the heat sinks to better do its job. There is no observed curing time. That is, performance does not get any better over time. Any curing time could have introduced variables into the equation causing at best dubious results and at worst unreliable ones.

Temperatures

Ambient temperature will be kept at 25C for the duration of the tests and measured with a MicroTemp EXP non-contact infrared thermometer and cross referenced with the Sperry Digital 4 Point thermometer. Any variance greater then 0.2C will halt the testing until temperatures return within spec for fifteen minutes.

Idle

Idle temperatures will be recorded after a twenty minute period of inactivity. Any fluctuation during the last sixty seconds will reset the timer for an additional five minutes.

Load

Load temperatures will be recorded after a twenty minute period for air cooled systems, and thirty minutes for liquid cooled systems, at 100% load. To obtain this load we will be using AIDA64 Extreme Edition v3.00.2500. This places an even greater load on the CPU than before and includes some benefits. Because the load is so extreme we see the temperature vary wildly from 72C to 86C in some instances. To get an accurate reading we will utilize AIDA64’s ability to average the temperature over time. Given twenty/thirty minutes at 100% load we arrive at a temperature that accurately represents our heatsink’s performance.

Sound

Sound levels will be measured with a Reliability Direct AR824 sound meter from a distance of four feet away. With everything turned off and the room completely silent the meter registered a sound level of 38dB(A). This is a very quiet room where a simple pin drop could be heard. All sound measurements are recorded in the very late evening to further reduce any ambient noise.